Issue 2 Page 1 of 2

CONVENTIONAL DEVICES

Fire Detection DevicesCR/CF-EWT SeriesExplosion Proof Heat Detectors

SECUTRON INC.Canada 25 Interchange Way, Vaughan (Toronto), Ontario L4K 5W3 Telephone: (905) 695-3545 Fax: (905) 660-4113 • Web Page: www.secutron.com

U.S.A. 4575 Witmer Industrial Estates, Niagara Falls, NY 14305 Telephone: (888) 695-3545 Fax: (888) 660-4113 • E-mail: [emailprotected] Catalog Number 2022 • Not to be used for installation purposes.

Description

The CR/CF-EWT series of fire alarm Heat Detectors provide reliable fire detection in areas which are classified as hazardous. They are ULC listed for hazardous location Class I, Groups C and D; Class II, Groups E, F and G; Class III Weatherproof, Watertight and Dust-tight applications covered by Special Purpose Enclosures III, IV and V.

All heat detectors in the CR/CF-EWT series are single pole with normally open contacts. The body with its explosion proof cover is made from cast aluminium and houses a thermostat with colour-coded wire leads and sealed terminals. The finish is natural aluminium. Threaded outlets for ½” rigid conduit connections are provided.

Two combination rate-of-rise and fixed temperature models are available. Model CR-135-EWT is rated for 135°F (57°C). Model CR-200-EWT is rated for 200°F (93°). Maximum spacing for both models is 50 feet (15.2m).

Two fixed temperature only models are available. Model CF-135-EWT is rated for 135°F (57°C). Model CF-200-EWT is rated for 200°F (93°C). Maximum spacing for these models is 30 feet (9.1m).

Features

Class I Groups C & D•

Class II Groups E, F & G•

Class III•

Weatherproof, Water-Tight & Dust-Tight•

Special Purpose Enclosure - III, IV, V•

Wire Leads/Sealed Connection•

Rate-Of-Rise and/or Fixed Temperature•

Single Pole - Normally Open Contact•

Low Profile•

Operation

CR-135-EWT and CR-200-EWT Rate-of-Rise Models: A temperature increase at the detector of 15°F (9°C) or more per minute activates the rate-of-rise feature. This closes the contacts in the detector to transmits the alarm condition to the fire alarm control panel. When the rate-of- rise element alone has been activated, the detector is self-restoring.

CF-135-EWT and CF-200-EWT Fixed Temperature Models: If the temperature of the centre disk rises to the detector’s rated temperature, the fixed temperature element activates. This closes contacts in the detector and transmit the alarm condition to the fire alarm control panel. The fixed temperature element is non-restorable and when activated, the detector must be replaced. The need for replacement is indicated when the centre disk has fallen free from the detector

(PDF) CONVENTIONAL DEVICES Fire Detection Devices Features CR/CF ...· CONVENTIONAL DEVICES Fire Detection Devices ... The CR/CF-EWT series of fire alarm Heat Detectors provide reliable - DOKUMEN.TIPS (2)

Page 2 of 2 Issue 2SECUTRON INC.Catalog Number 2022 • Not to be used for installation purposes.

Secutron reserves the right to make changes at any time without notice in prices, colors, materials, components, equipment, specifications and models and also to discontinue models.Modul-R® is a trademark of Secutron Inc.

Ordering Information

SpecificationsCatalogue Number CR135EWT CR200EWT CF135EWT CF200EWT CF285EWT

ULC Temperature Rating 135 °F (57 °C) 200 °F (93 °C) 135 °F (57 °C) 200 °F (93 °C) 285 °F (140 °C)

ULC Maximum AmbientTemperature at Ceiling

100 °F (38 °C) 150 °F (66 °C) 100 °F (38 °C) 150 °F (66 °C) 224 °F (107 °C)

Detector Operation Fixed Temperature and Rate-of-Rise Fixed Temperature Only

ULC RecommendedCoverage - see note A

2500 ft2 (232m2) 900ft2 (83m2)

ULC Recommended Spacing 50 ft (15.2m) 30ft (9.1m)

ULC Maximum Distance fromWall - see note B

25 ft (7.6m) 15 ft (4.6m)

ULC Approvals Listed for Hazardous Location Class I, Groups C and D; Class II, Groups E, F and G; Class IllWeatherproof, Water-tight and Dust-tight Applications covered by Special Purpose EnclosuresIll, IV and V

Other Approvals C.S.A.; UL

Contacts Single Pole Normally Open - Rated at: 3.0 amps at 6 to 125V ac; 1.0 amps at 6 to 28V dc; 0.3amps at 125V do; 0.1 amp at 250V dc

Note A - Maximum detector coverage has been determined by ULC to provide detection time equal to sprinkler devices spaced at 10 ft.(3m) intervals on a smooth ceiling 15 ft 9 in. (4.8m) high. Higher ceilings can adversely affect detection time. In some Instances.earlier detection time may be obtained by reducing the spacing between the detectors. Refer to the latest edition of CAN/ULC-S524. Standard for the Installation of Fire Alarm Systems, section on Heat Detectors.

Note B - Maximum distance shown is from any wall partition or ceiling projection extending down more than 12 inches (305mm).

Typical Wiring

Model DescriptionCR-135-EWT Rate of Rise & Fixed Temperature 135°F Explosion Proof Heat Detector

CR-200-EWT Rate of Rise & Fixed Temperature 135°F Explosion Proof Heat Detector

CF-135-EWT Fixed Temperature 135°F Explosion Proof Heat Detector

CF-200-EWT Fixed Temperature 135°F Explosion Proof Heat Detector

(PDF) CONVENTIONAL DEVICES Fire Detection Devices Features CR/CF ... · CONVENTIONAL DEVICES Fire Detection Devices ... The CR/CF-EWT series of fire alarm Heat Detectors provide reliable - DOKUMEN.TIPS (2024)

FAQs

What is a CR heat detector? ›

A high-quality Type CR static/rate of rise heat detector. Monitors temperature using a dual thermistor network which provides a voltage output proportional to the external air temperature.

What are the four main types of fire alarm systems? ›

The four most common detectors are ionisation, photoelectric, combination ionisation/photoelectric, and heat. All smoke detectors sound an alarm, when they identify smoke, to notify a building's occupants. What differentiates these detectors from one another is the way that they detect smoke.

What is the standard for a fire alarm system? ›

ISO 7240-14, the international standard for the design, installation, commissioning, and service of fire detection and fire alarm systems in and around a building.

Is a fire alarm system AC or DC? ›

This type operates by combining alternating current (AC) with direct current (DC). It can provide both AC and DC output to operate various components in a fire alarm system, such as smoke detectors and alarm panels. Additionally, it usually contains backup batteries in case of a main power failure.

How do I test my heat detector? ›

We do a heat test on them and they need to have a response within 60 seconds after activating the heat on the device. A lot of times we use either a hair dryer or a heat gun that is the heat source. Don't use a lighter, a Bic lighter will actually melt the detector housing.

How to tell the difference between a smoke and heat detector? ›

Smoke alarm or heat alarm – what's the difference? Smoke alarms detect smoke – fit them in all rooms where a fire might start. But in smoky or steamy rooms like your kitchen or bathroom, a heat alarm is more suitable. These alarms go off when the room reaches a certain temperature.

Can anyone install a fire alarm system? ›

If you're installing a battery-powered alarm system then you should be able to easily and quickly do the job yourself. For any of the wired alarm systems, we would recommend hiring a local fire alarm expert to carry out the installation. That way you know it's installed safely and securely.

What is the difference between conventional and addressable fire alarm systems? ›

An addressable fire alarm system involves devices each connected to their own address. Unlike a conventional alarm system that relies on zones, addressable systems detect a fire which then shows up on the main control panel, sharing exactly what device detected it.

Is a smoke detector required at the fire alarm control panel? ›

4 - Areas that are not continuously occupied, properly protected In areas that are not continuously occupied, automatic smoke detection shall be provided at the location of each fire alarm control unit(s), notification appliance circuit power extenders, and supervising station transmitting equipment to provide ...

How do you tell if a smoke detector is a hidden camera kidde? ›

Turn off the lights in the room and place your mobile camera in front of the smoke detector. Look for any infrared lights that appear on the screen, as these may show the presence of a hidden camera. If you observe either white or purple lights, there is likely a hidden camera within the smoke detector.

Why is my smoke detector chirping? ›

Your smoke detectors don't have an inside voice — for your safety. If you hear your smoke detector beeping in brief chirps every 30-60 seconds, it's probably time to replace the battery. Or you might need to clean out the dust, check the battery connections or replace the whole smoke alarm.

What is a Class C fire alarm system? ›

Grade C under BS5839-6 is a system of separate fire detectors and alarm sounders (which may be combined in the form of smoke alarms) that are mains powered with back-up power supply and with a central element of control (panel or control switch).

What are the three types of heat detectors? ›

Heat detectors come in three varieties: rate-of-rise, fixed temperature, and a combination of rate-of-rise and fixed temperature.

What is the purpose of a heat detector? ›

Put simply, a heat detector - or heat alarm - is a device that's used to detect any substantial increase in temperature which may indicate a fire is about to break out.

What are the two types of heat detectors fixed and _________ detectors? ›

There are two major styles of heat detectors: rate-of-rise heat detectors and fixed temperature detectors. These two detectors use different types of sensors to do the same job: respond to high amounts of thermal energy from the fire – to detect the heat being given off.

What is a CS heat detector? ›

The AlarmSense Heat Detector (CS) responds when a fixed temperature has been reached. Can be used for applications where smoke detectors are unsuitable. Ideal environments that are dirty or smoky under normal conditions. 360°C visibility of LEDs. Reduction of false alarms.

References

Top Articles
Latest Posts
Article information

Author: Allyn Kozey

Last Updated:

Views: 6196

Rating: 4.2 / 5 (43 voted)

Reviews: 90% of readers found this page helpful

Author information

Name: Allyn Kozey

Birthday: 1993-12-21

Address: Suite 454 40343 Larson Union, Port Melia, TX 16164

Phone: +2456904400762

Job: Investor Administrator

Hobby: Sketching, Puzzles, Pet, Mountaineering, Skydiving, Dowsing, Sports

Introduction: My name is Allyn Kozey, I am a outstanding, colorful, adventurous, encouraging, zealous, tender, helpful person who loves writing and wants to share my knowledge and understanding with you.